Cn40 Temperature Controller User Manual

On

Cn 40 Temperature Controller Manual. CN-40 (Digital Process/Temperature Controller),complete details about CN-40.

User's Guide
  • Toho CN-40 Digital Controller. User manual The STLUX385A digital controller drives both stages.
  • This manual gives detailed description of the precautions that should be brought to your attention during operation. In order to ensure correct service of the wired controller.
ME-PC11121_Ver1.0

Advertisement

Related Manuals for Sure Electronics Remote Temperature Controller

Summary of Contents for Sure Electronics Remote Temperature Controller

  • Page 1 Remote Temperature Controller User’s Guide © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0...
  • Page 2: Table Of Contents

    2.3 Description of The Remote Control’s Keys ............4 2.4 Working Mode Setting ..................7 Chapter 3. Electrical Characteristics ................8 Chapter 4. Mechanical Drawing..................9 Chapter 5. Appendix ......................10 Chapter 6. Contact Us ..................... 11 © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page i...
  • Page 3 Remote Temperature Controller NOTES: : Product Version Ver 1.0 : Document Version Ver 1.0 © 2004-2010 Sure Electronics Inc ME-PC11121_Ver1.0_Page ii...
  • Page 4: Chapter 1. Overview

    Chapter 1. Overview 1.1 Overview Thanks for using this remote temperature controller by Sure Electronics. This product is populated with a high performance 8-bit PIC16F690 as the main chip, 7-segment LED display is used as the display of temperature readings, timing and the settings, a relay to control the external heating or cooling devices, a IR receiver receiving signals from the 7-key battery-powered remote control.
  • Page 5: Applications

    2. Power the panel meter with a supply (12VDC) as follows. FIGURE 1-4 CONNECTION SCHEMATIC 3. Then the temperature from the digital probe is displayed on the panel meter. FIGURE 1-5 TEMPERATURE DISPLAY © 2004-2010 Sure Electronics Inc ME-PC11121_Ver1.0_Page 2...
  • Page 6: Chapter 2. Setting

    Utilize Time Relay mode. Before the set time: relay open; time up: MOD5 relay closed. Regularly open the external devices. Utilize Time Relay mode. Before the set time: relay close; time up: MOD6 relay open. Regularly close the external devices. © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 3...
  • Page 7: Description Of The Remote Control's Keys

    FIGURE 2-2 OVERVIEW OF THE REMOTE CONTROL TABLE 2-3 7-KEY INFRARED REMOTE CONTROL Symbol Function Symbol Function ON/OFF Up (++) Up (+) Down (--) Down (-) SETOFF © 2004-2010 Sure Electronics Inc ME-PC11121_Ver1.0_Page 4...
  • Page 8 Working example, the current working mode mode is mod0. Continuously setting pressing key2(+), the working mode will switch in a cycle of mod0→mod1→mod2→mod3→ mod4→mod5→mod6→mod0. © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 5...
  • Page 9 The timing will pause when you press any key. Do not press any key during timing, or the timing won’t be accurate. During normal temperature display, unplug or plug the DS18B20 will cause temporary wrong display (85℃/185℉) but without other affect. © 2004-2010 Sure Electronics Inc ME-PC11121_Ver1.0_Page 6...
  • Page 10: Working Mode Setting

    →SET→ - →-(mode5) →OK specific time External devices need to SET→SET→SET→SET→+/-(time setting) MOD6 Time relay be closed at a →SET→- (mode6) →OK specific time Note: ℃/℉ setting: SET→ SET→SET→ +/- →OK. © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 7...
  • Page 11: Chapter 3. Electrical Characteristics

    Insulation Resistance(DC500V) 1,000 MΩ Lifetime Mechanical Lifetime (10,800 times/hour) 10,000,000 times Electrical Lifetime (1,800 times/hour) 100,000 times Remote Control Angle ° Distance Encoding Format Physical/Environmental Operating Temperature °C Storage Temperature °C Humidity © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 8...
  • Page 12: Chapter 4. Mechanical Drawing

    REMOTE TEMPERATURE CONTROLLER USER’S GUIDE Chapter 4. Mechanical Drawing FIGURE 4-1 MECHANICAL DRAWING OF FRONT PANEL FIGURE 4-2 MECHANICAL DRAWING OF BACK PANEL FIGURE 4-2 MECHANICAL DRAWING OF BASE PANEL © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 9...
  • Page 13: Chapter 5. Appendix

    CONTROLLER USER’S GUIDE Chapter 5. Appendix Due to the performance limitation of 7-segment display, some letters and digits are constructed with special segment architecture. The letters-digits table is as follows: TABLE 5-1 LETTERS-DIGITS © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 10...
  • Page 14: Chapter 6. Contact Us

    Chapter 6. Contact Us Sure Electronics Co., Ltd. East zone, 3F, Building 6 Jingang Technology Innovation Center No.108 Ganjiabian Rd (ZIP: 210000) Qixia District Nanjing P.R.China Tel: +86-25-68154800-860 Fax: +86-25-68154891-832 Website: www.sure-electronics.com Email: customerservice@sure-electronics.com © 2004-2010 Sure Electronics Inc. ME-PC11121_Ver1.0_Page 11...
Split type room air conditioner ceiling wall type nverter.
Hide thumbs Also See for AWYZ24LBC
Service manual - 27 pages
Installation manual - 2 pages
Operating manual - 26 pages
ROOM AIR CONDITIONER
INVERTER
Indoor unit
AWYZ24LBC
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 1
REFRIGERANT SYSTEM DIAGRAM . . . . 4
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . 5
OUTDOOR PCB CIRCUIT DIAGRAM . . . 10
DISASSEMBLY ILLUSTRATION . . . . . . .
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . .
type
16

Advertisement

Also See for Fujitsu AWYZ24LBC

Related Manuals for Fujitsu AWYZ24LBC

  • Air Conditioner Fujitsu AWYZ14LBC Service Manual
    Split type room air conditioner ceiling wall type inverter (14 pages)
  • Air Conditioner Fujitsu AWY24LBAJ Service Manual
    (27 pages)
  • Air Conditioner Fujitsu AWY24FBAJ Service Manual
    Split type room air conditioner (31 pages)
  • Air Conditioner Fujitsu AW*Z24LBC Service Instruction
    Ceiling wall inverter (97 pages)
  • Air Conditioner Fujitsu AWTZ14LBC Operating Manual
    Ceiling wall type heat & cool model (reverse cycle) (28 pages)
  • Air Conditioner Fujitsu AWU18CXQ Service Manual
    (48 pages)

Summary of Contents for Fujitsu AWYZ24LBC

  • Page 1: Table Of Contents

    SPLIT TYPE ROOM AIR CONDITIONER CEILING WALL type INVERTER Models Indoor unit Outdoor unit AWYZ24LBC AOYZ24LBT CONTENTS SPECIFICATIONS ....1 OUTLINE AND DIMENSIONS ..2 REFRIGERANT SYSTEM DIAGRAM .
  • Page 2: Specifications

    SPECIFICATIONS COMPRESSOR Cooling and heating inverter TYPE Hermetic type, DC Inverter, TYPE Twin rotary INDOOR UNIT AWYZ24LBC DISCRIMINATION 5KD240XAD21 OUTDOOR UNIT AOYZ24LBT R410A 1,900 g REFRIGERANT COOLING CAPACITY 7.1 kW HEATING CAPACITY 8.5 kW REFRIGERANT CHARGE (R410A) ELECTRICAL DATA Pipe Length 15 m 1,900 g 230 V 50 Hz...
  • Page 3 DIMENSIONS INDOOR UNIT (Unit : mm) 2006.10.20...
  • Page 4 OUTDOOR UNIT (unit : mm) Air Flow 2006.10.18...
  • Page 5: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM Heat exchanger ( INDOOR ) 3-Way valve (Large) 3-Way valve Muffler (Small) Pressure Strainer switch Expansion valve 4-Way valve Heat exchanger Strainer ( OUTDOOR ) Cooling Heating Refrigerant pipe diameter Liquid : 1/4' (6.35 mm) Gas : 5/8' (15.88 mm) 2006.10.18...
  • Page 6: Circuit Diagram

    CIRCUIT DIAGRAM INDOOR UNIT AIR FILTER (LEFT) SW (LEFT) THERMAL FUSE 102 AIR FILTER (RIGHT) INDICATOR PCB SW (RIGHT) CN208 1 2 3 4 5 1 2 3 4 5 6 7 8 1 2 3 4 5 THERMAL FUSE 102 CONNECTOR (RED) BROWN 1 2 3 4 5...
  • Page 7 OUTDOOR UNIT HIGH PRESSUR SWITCH CN90 COMPRESSOR TEMP. THERMISTOR BROWN CN64 BROWN CN400 CN42 CN40 CN200 OUTDOOR TEMP. THERMISTOR BLUE CN62 BLUE PIPE TEMP. THERMISTOR BLACK CN61 BLACK CONTROLLER PCB DISCHARGE TEMP. THERMISTOR ( MAIN PCB ) BROWN CN60 BROWN BLACK CN303 CN301...
  • Page 8 PCB Circuit Diagrams not available at time of publication...
  • Page 9: Error Contents

    ERROR CONTENTS Display Error Error Operation Timer LED 2 flash Serial signal (reverse) error, at operation start up 3 flash Serial signal (reverse) error, during operation Serial signal error 4 flash Serial signal (forward) error, at operation start up 5 flash Serial signal (forward) error, during operation 2 flash Indoor temperature thermistor open / short...
  • Page 10: Disassembly Illustration

    DISASSEMBLY ILLUSTRATION INDOOR UNIT 2006.10.20...
  • Page 11 INDOOR UNIT Casing assy 2006.10.20...
  • Page 12 INDOOR UNIT 2006.10.20...
  • Page 13 OUTDOOR UNIT 2006.10.18...
  • Page 14 OUTDOOR UNIT 2006.10.18...
  • Page 15 OUTDOOR UNIT 2006.10.18...
  • Page 16 OUTDOOR UNIT DISCHARGE TEMP THERMISTOR CONNECTOR : ORANGE OUTDOOR TEMP THERMISTOR CONNECTOR : BLUE COMPRESSOR TEMP THERMISTOR CONNECTOR : GREEN HEAT EXCHANGER THERMISTOR CONNECTOR : RED PRESSURE SWITCH WIRE CONNECTOR : RED 2006.10.18...
  • Page 17: Parts List

    PARTS LIST INDOOR UNIT Part No. Ref. Ord. Description AWYZ24LBC Q'ty Air Filter 9313859015 Dust Box Assy 9313884024 Front Panel Total Assy 9313882105 Open Panel Assy 9314405020 Top Grill 9313848019 Under Cover 9313850029 Casing Assy 9313877040 Louver U Assy 9312243037 Louver U 9311993032 Louver Frame...
  • Page 18 OUTDOOR UNIT Part No. Ref. Ord. Description Q'ty AOYZ24LBT Top Panel Sub Assy 9374417032 Front Panel 9374094066 Fan Guard 9374330010 Grip Side 9374173013 Service Panel Sub Assy 9374415052 Right Panel Sub Assy 9374416127 Emblem Rear 9351355005 Propeller Fan Assy 9366378020 Motor, DC Brushless 9601882015 Condenser A Assy...
  • Page 19: Standard Accessories

    STANDARD ACCESSORIES The following installation accessories are supplied. Use them as required. Name and Shape Q'ty Name and Shape Q'ty Wall hook bracket Drain pipe 9301102000 9312011018 Cloth tape Remote control unit 9308117007 Tapping screw (big) 9315029010 Battery 0700076046 Tapping screw (small) 0600185046 0700019036 Remote control unit...
  • Page 20 0610G3168...